Synuclein Alpha (SNCa) BioAssay ELISA Kit (Mouse)

£1,007.00 96 Tests

Synuclein Alpha (SNCa) BioAssay ELISA Kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of SNCa in mouse serum, plasma, tissue homogenates, cell lystaes, cell culture supernants and other biological fluids.

SKU: US028278 Categories: , ,

Additional information

Detection Range

78-5000pg/ml

Sensitivity

27pg/ml

Precision

Intra-Assay:
CV<10%

Inter-Assay:
CV<12%

Kit Components

*028278A: Microtiter Strips, 1×48 wells or 1×96 wells, Pre-coated, ready to use
*028278B: Standard, 2×1 vial
028278C: Standard Diluent, 1x10ml or 1x20ml
*028278D: Detection Reagent A (green), 1x60ul or 1x120ul
*028278E: Detection Reagent B (red), 1x60ul or 1x120ul
028278F: Assay Diluent A, 1x6ml or 1x12ml
028278G: Assay Diluent B, 1x6ml or 1x12ml
028278H: TMB Substrate, 1×4.5ml or 1x9ml
*028278J: Positive Control, 186.2pg/ml, 1x1vial
028278K: Stop Solution, 1x3ml or 1x6ml
028278L: Wash Buffer, 30X, 1x10ml or 1x20ml

Precaution

The Stop Solution (028278K) included for use in this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

Storage and Stability

Store *028278A, *028278B, *028278D, *028278E and *028278J at -20?C. After reconstitution of *028278J, store at 4?C and use within 5 days. Store all the other components at 4?C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.

Notes on 028278J

Positive Control

Intended Use

The control vials are from mouse serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly.

Characteristics

The control vials contain mouse SNCa in mouse serum (lyophilized powder). Note: The mouse based material used in this product is from healthy mice of SPF standard (specific pathogen-free animals).

Expected Values

186.2pg/ml
The concentration of the control was determined by subtracting two standard deviations to the mean optical density value of twenty QC sample replicates and calculating the corresponding concentration.

Usage

Disslove with 150ul standard dilutent and let stand for 10 minutes. Mix gently before use. In the experiment, add 50ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: After reconstitution, store Positive Control vial at 4?C and use within 5 days.

Assay Procedure Summary

1. Prepare all reagents, samples and standards.
2. Add 100ul standard or sample to each well. Incubate 1 hour at 37?C.
3. Add 100ul prepared Detection Reagent A. Incubate 1 hour at 37?C.
4. Aspirate and wash 3 times.
5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37?C.
6. Aspirate and wash 5 times.
7. Add 90ul Substrate Solution. Incubate 10-20 minutes at 37?C.
8. Add 50ul Stop Solution. Read at 450nm immediately.

Shelf Life