Mucin 5 Subtype AC (MUC5AC) BioAssay ELISA Kit (Human)

£960.00 96 Tests

Mucin 5 Subtype AC (MUC5AC) BioAssay ELISA Kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of MUC5AC in human tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

SKU: US026903 Categories: ,

Additional information

Detection Range

78-5000pg/ml

Sensitivity

30pg/ml

Precision

Intra-Assay CV:
<10%

Inter-Assay CV:
<12%

Kit Components

*026903A: Microtiter Strips, 1×48 wells or 1×96 wells, Pre-coated, ready to use
*026903B: Standard, 2×1 vial
026903C: Standard Diluent, 1x10ml or 1x20ml
*026903D: Detection Reagent A (green), 1x60ul or 1x120ul
*026903E: Detection Reagent B (red), 1x60ul or 1x120ul
026903F: Assay Diluent A, 1x6ml or 1x12ml
026903G: Assay Diluent B, 1x6ml or 1x12ml
026903H: TMB Substrate, 1×4.5ml or 1x9ml
026903J: Positive Control, 823.2pg/ml, 1x1vial (Lyophilized)
026903K: Stop Solution, 1x3ml or 1x6ml
026903L: Wash Buffer, 30X, 1x10ml or 1x20ml

Precaution

The Stop Solution (026903K) included for use in this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

Storage and Stability

Store *026903A, *026903B, *026903D, *026903E and *026903J at -20?C. After reconstitution of *026475J, store at 4?C and use within 5 days. Store all the other components at 4?C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.

Notes on 026903J

Positive Control

Intended Use

The positive control is from a human sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly.

Characteristics

The positive control vial contains human MUC5AC in human sample (lyophilized powder). Note: The human based material used in this product is screened for HIV, Hepatitis A, B, C, HTLV and Syphilis.

Expected Values

823.2pg/ml

Usage

Dissolve with 150ul standard diluent and let stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 100ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20?C. After reconstitution, store Positive Control vial at 4?C and use within 5 days.

Assay Procedure Summary

1. Prepare all reagents, samples and standards.
2. Add 100ul standard or sample to each well. Incubate 1 hour at 37?C.
3. Aspirate and add 100ul prepared Detection Reagent A. Incubate 1 hour at 37?C.
4. Aspirate and wash 3 times.
5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37?C.
6. Aspirate and wash 5 times.
7. Add 90ul Substrate Solution. Incubate 10-20 minutes at 37?C.
8. Add 50ul Stop Solution. Read at 450nm immediately.

Shelf Life

6 Months