Interleukin 11, Human (IL-11) BioAssay ELISA Kit

£943.00 96 Tests

This IL-11 enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific to IL-11. Standards or samples are then added to the appropriate microtiter plate wells and incubated. After washing to remove unbound IL-11 and other components of the sample, biotin-conjugated polyclonal antibody specific to IL-11 is added and incubated. If present, IL-11 will bind and become immobilized by the antibody pre-coated on the wells and then become ?sandwiched? by the biotin conjugate. In order to quantitatively determine the amount of IL-11 present in the sample, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Avidin is a tetramer containing four identical subunits, each having a high affinity-binding site for biotin. The wells are thoroughly washed to remove all unbound HRP-conjugated Avidin and a TMB (3,3’5,5′ tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain IL-11, biotin-conjugated antibody, and enzyme-conjugated Avidin will exhibit a change in colour. The enzyme- substrate reaction is terminated by the addition of a sulphuric acid solution and the colour change is measured spectrophotometrically at a wavelength of 450nm ? 2nm.

In order to measure the concentration of IL-11 in the samples, this kit includes two calibration diluents (Calibrator Diluent I for serum/plasma testing and Calibrator Diluent II for cell culture supernatant testing). According to the testing system, the provided standard is diluted (2-fold) with the appropriate Calibrator Diluent and assayed at the same time as the samples. This allows the operator to produce a standard curve of Optical Density (O.D) versus IL-11 concentration (pg/ml). The concentration of IL-11 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Additional information

Sensitivity

Calibrator Diluent I: 4pg/ml
Calibrator Diluent II: 3pg/ml

Range

0-1600pg/ml

Kit Components

I8433-10B1: Microtiter Plate, 1×96 wells
I8433-10B2: IL-11 Pab (Biotin), 1x7ml
I8433-10B3: Avidin (HRP), 1x14ml
*I8433-10B4: IL-11 Standard, 2×1 vial
I8433-10B5: Calibrator Diluent I, 1x25ml
I8433-10B6: Calibrator Diluent II, 1x25ml
I8433-10B7: Wash Buffer (20X), 1x60ml
I8433-10B8: Substrate A, 1x10ml
I8433-10B9: Substrate B, 1x10ml
I8433-10B10: Stop Solution, 1x14ml

Storage and Stability

Store *I8433-10B4 powder at 4°C liquid at -20°C. Store other components at 4°C. Stable for 6 months For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap.

Shipping Temperature

On Dry Ice

Source Antigen

Human

Shelf Life

6 Months